EDIT: fucking switch doesnt fit in the wall coz of the control box so brb

TLDR: is a Neutral wire in a “live + neutral + ground” setup the load output wire or a neutral wire when doing light switches?

My house is ca. 1907 for context, and the only wires I’ve got are:

  1. Red (Live), tested with multimeter.
  2. Grey (Neutral…?), was connected to common terminal of old (traditional) switch
  3. Exposed (Ground?) Connected to terminal housing.

My new dimmer supports “with or without neutral” circuits:

but what confuses me is how the 2nd wire is a neutral line, but clearly is being used as common; should this be connected as neutral, or do I have a “no neutral” circuit setup?

I’ve got some old wiring from the cellar to demonstrate what I think is correct, including some ground wire taped up to connect the L+N terminals as the circuit describes:

(NB: Brown is Live, Blue is Neutral, this wire postdates the house by a LOT)

    • aanes_appreciator [he/him, comrade/them]@hexbear.netOP
      link
      fedilink
      English
      arrow-up
      2
      ·
      10 months ago

      Yeah the house is an ex rental so the wiring will have been redone to meet regular council inspections, so it’s more modern than that! Useful diagram btw.

      Good to know I’m not crazy thinking that it’s DEFINITELY a neutral wire. I think the UK’s terminology is a bit of an arse because in switch circuits the neutral appears to be called a “common”… i think

      In the end, I did just do as the pic showed but with clips to combine the live terminals. Annoyingly it both made a shite connection and the lack of load on neutral made it flicker a bit so it’s back to the flicker switch for now.

      I’ll come back to it when I’ve got those hits sorted :) ty!

  • trompete [he/him]@hexbear.net
    link
    fedilink
    English
    arrow-up
    3
    ·
    10 months ago

    I mean it has to be the load output, how else would that work. In order to make a circuit, it needs to be live - switch - lamp - neutral. If you just had live and neutral, the circuit would be live - switch - neutral, which I guess would make a funny let’s blow the fuse prank switch or something.

  • Yllych [any]@hexbear.net
    link
    fedilink
    English
    arrow-up
    2
    ·
    10 months ago

    Not too familiar with British wiring, but I am thinking your brown wire is a switch leg that goes directly to the light itself. If you go to the light you’re wanting to control, do you have the same red and brown wire? You could use your multimetre to ring the wires out and determine what is going where to be certain.

    • aanes_appreciator [he/him, comrade/them]@hexbear.netOP
      link
      fedilink
      English
      arrow-up
      2
      ·
      10 months ago

      I did more researching and you’re right. neutral is used as the switch leg as you call it. Here’s it’s called a “common” line. Some circuits will have a second live wire that takes the place of “common” so the Neutral would be used in that case, but the naming conventions confused me 😅